Industrial Power Sources and Where Boilers Fit

Throttle used in locomotive boiler

Industrial plants draw on a few energy sources: electricity from the grid or generated on site, fuel burned on site, and heat recovered from other equipment. Industrial boilers sit in the middle of that picture. They turn fuel or electricity into steam or hot water, which carries heat to processes and buildings; in most plants the boiler is a heat source, and the power for motors and lights comes from the grid. McKenna Boiler Works, Inc. builds firetube, firebox, and vertical boilers, and this post explains where a boiler fits among a plant’s energy options and how to compare them for process heat in California.

What does a boiler do that other energy sources do not?

Steam is a way to move heat. A boiler puts heat into water, and the steam carries it through piping to a kettle, a sterilizer, a press, a heat exchanger, or a coil, where it condenses and gives up its latent heat at a fixed temperature set by its pressure. At atmospheric pressure, each pound of steam gives up about 970 Btu as it condenses. Saturated steam at 15 psig condenses at about 250°F; at 100 psig, about 338°F; at 150 psig, about 366°F. That fixed, controllable temperature is why steam remains the default for sterilizing, cooking, curing, and many chemical processes. Hot water does the same job for building heat and lower-temperature processes.

Electricity runs motors, compressors, lighting, and controls, and it can also make heat directly. Direct-fired equipment, such as ovens, dryers, and furnaces, burns fuel at the point of use without a boiler. A plant usually uses all three, and the question is which one should supply each heat load.

How do the options compare for process heat?

SourceHow heat reaches the processStrengthsConstraints
Gas-fired boilerSteam or hot water through a distribution systemServes many users from one plant; handles load swings; steady temperatureAir district NOx and CO limits; combustion tuning; distribution and condensate losses
Electric boilerSteam or hot water, same distributionNo on-site combustion emissions, no stackElectricity cost per unit of heat; electrical service capacity
Direct-fired equipmentFlame or hot gas at the point of useNo distribution losses for that loadEach unit needs its own burner, permit, and maintenance
Heat recovery (economizers, condensate return, waste heat)Preheats feedwater, makeup water, or a process streamUses heat already paid forLimited to heat available at the right time and temperature
Combined heat and powerAn engine or turbine makes electricity; its exhaust or jacket heat makes steam or hot waterUses fuel for power and heat togetherNeeds a steady heat load matched to the power output; its own air permit

How do you compare fuel and electricity costs?

The fair comparison is the cost of heat delivered into the water. One therm is 100,000 Btu, and one million Btu (MMBtu) is ten therms or about 293 kWh.

  • Gas boiler: cost per MMBtu delivered = (price per therm × 10) ÷ boiler efficiency.
  • Electric boiler: cost per MMBtu delivered = price per kWh × 293, divided by an efficiency close to 1.

With illustrative prices of $1.00 per therm and a gas boiler at 80 percent efficiency, delivered heat costs $12.50 per MMBtu. At $0.20 per kWh, electric heat costs about $58.60 per MMBtu. Use your own tariffs, including demand charges and time-of-use rates for electricity, and your boiler’s measured efficiency. The ratio between your gas and electric prices drives the answer more than any equipment choice.

Electrical service is often the harder constraint. Converting a large steam load to electricity can require a new service, transformer, and switchgear, and the utility’s timeline for that work.

What sets the limits on gas-fired boilers in California?

Air districts regulate NOx and CO from boilers by size. South Coast AQMD Rule 1146 covers units of 5 million Btu per hour heat input and larger, Rule 1146.1 units above 2 and below 5 million Btu per hour, and Rule 1146.2 smaller units. The San Joaquin Valley applies Rules 4306 and 4320 to units above 5 million Btu per hour, and Bay Area Regulation 9, Rule 7 covers units above 2 million Btu per hour. These limits are why new boilers in California are fitted with low NOx burners matched to the limit, and why older boilers often need an ultra low NOx retrofit to keep running. Meeting the limit depends on the burner and on tuning; see combustion tuning.

Safety rules also apply to the fuel side: ASME CSD-1 for automatically fired boilers up to 12.5 million Btu per hour input, NFPA 85 above that, and Cal/OSHA’s Boiler and Fired Pressure Vessel Safety Orders for inspection and the permit to operate on power boilers.

What to ask before changing a plant’s heat source

  1. What temperature does each process actually need? Lowering steam pressure to the minimum that meets the process reduces losses.
  2. What is the measured load and how does it swing? Use fuel and steam meter data; the boiler sizing calculator converts units.
  3. How much condensate comes back? Every pound returned saves the heat and water treatment it carries.
  4. What are your gas and electric tariffs, including demand charges, and what will the utility need to supply an electric load?
  5. What NOx and CO limits will apply to a new or modified gas-fired unit in your district?
  6. Can existing controls be upgraded before replacing equipment? See control and efficiency upgrades.
  7. For any work on fuel trains or pressure parts, follow the manufacturer’s instructions, lockout/tagout, and your site’s procedures, and never bypass a safety control during a changeover.

Common questions

Is steam a power source?

In most industrial plants, steam is a heat carrier. A boiler converts fuel or electricity into steam, and the steam delivers that heat to processes. Power plants use steam to drive turbines, but that is rare in a typical manufacturing plant.

Are electric boilers cheaper to run than gas boilers?

It depends on your rates. Compare the cost per MMBtu delivered using your gas price, your boiler’s efficiency, and your full electric tariff. Electric boilers avoid combustion emissions on site, which matters under tight air district limits.

Does McKenna make electric boilers?

McKenna’s electric boiler is in development, with no release date. McKenna builds gas-fired firetube, firebox, and vertical boilers with burners matched to the boiler and the emissions limit.

What is combined heat and power?

Combined heat and power uses an engine or turbine to generate electricity and recovers its exhaust or cooling heat to make steam or hot water. It fits plants with a steady heat load that matches the generator’s output. It needs its own air permit and interconnection agreement with the utility.

What is the cheapest heat a plant can add?

Usually heat it already has: more condensate returned, a stack economizer preheating feedwater, or a lower steam pressure where the process allows. Those cut fuel use without adding a new energy source.

Planning a heat source

To compare a new firetube boiler, a retrofit, or an upgrade for your plant, call McKenna at (323) 987-1816.

Need help with your boiler? McKenna Boiler Works, Inc. builds, installs, and services industrial boilers across California, and services and repairs other brands. Call (323) 987-1816 or request service.

Firetube boiler tubesheet with the old tubes removed during a McKenna retube

Retube or Replace a Firetube Boiler: How to Decide

Leaking or thinning tubes do not always mean a new boiler. Here is how to decide between a retube and

Read article →

Welding at a firetube boiler tubesheet

Boiler R Stamp Repair: What It Involves and When You Need One

Replacing tubes or welding on a shell, tubesheet, furnace, or nozzle is code work under the National Board Inspection Code.

Read article →

McKenna feedwater tank on a stand with duplex feed pumps below and water softeners beside it

Water Treatment and Its Impact on Industrial Boiler Reliability

Scale, oxygen pitting, and carbonic acid shorten boiler life. How each mechanism works, what a treatment program includes, and who

Read article →