Industrial Firetube Boilers, 5 to 800 Horsepower

Dryback and wetback Scotch marine boilers for steam and hot water, built to ASME Section I or Section IV in our California code shop. Standard sizes, or custom-designed to your load and boiler room.

SHMU
ASME S · H · M · U

Code-built boilers and vessels

National Board R

Code repairs and alterations

Autoflame
Autoflame

Factory-authorized Tech Center

Limpsfield
Limpsfield

Factory-authorized Burner Tech Center

McKenna flame
Since 1921

Fifth generation, family-owned

QUICK ANSWER

McKenna Boiler Works, Inc. is a firetube boiler manufacturer in Oceanside, California, building Scotch marine boilers from 5 to 800 HP. They are stamped to ASME Section I or IV for steam at 15, 150, or 250 psig and hot water at 125 psig. Wetback designs start at 100 HP. Low NOx and ultra-low NOx designs reach as low as 2.5 ppm NOx (corrected to 3% O2) on select models. For boilers of 2,000,000 Btu/hr or less, McKenna has units pre-certified to South Coast AQMD Rule 1146.2. Call (323) 987-1816.

At a glance

Firetube boiler specifications.

Every McKenna firetube boiler is built to order. These are the ranges we build to; your proposal lists the exact rating, dimensions, and trim.

Type

Scotch marine firetube

Designs

Two-pass dryback, two-pass wetback, three-pass wetback

Size range

5 to 800 HP dryback; 100 to 800 HP wetback

Design pressures

Steam: 15, 150, and 250 psig. Hot water: 125 psig

Media

Steam or hot water

Code

ASME Section I (S stamp) or Section IV (H stamp)

Burner and controls

A burner matched to the boiler and the emissions limit, with Autoflame controls as a standard option. Prefer a specific burner? McKenna also installs and tunes burners and controls from other manufacturers, including a brand your engineer specified

Fuels

Natural gas or propane. No. 2 oil as a backup fuel, or dual fuel. Hydrogen and hydrogen blends with a burner rated for them

Burner package

Piped, wired, and tested in our shop before the boiler ships

Service access

Full access to the tubes, tubesheet, and furnace. Standard, off-the-shelf replacement parts, not proprietary ones

Built

Standard sizes or custom to your spec and room

NOx

Low NOx and ultra-low NOx, as low as 2.5 ppm NOx (corrected to 3% O2) on select models

2,000,000 Btu/hr or less

Units pre-certified to South Coast AQMD Rule 1146.2

Sizing

Not sure which size you need?

Send us the steam or hot water load, the pressure, and the room. A McKenna engineer will size the boiler and get back to you.

Three designs

Dryback or wetback.

Not sure which fits your plant? A McKenna engineer will tell you plainly, based on your load, hours of operation, and maintenance crew.

Two-pass dryback firetube boiler cutaway showing gases turning in a refractory-lined rear chamber

Two-pass dryback

5 to 800 HP

Two-pass wetback firetube boiler cutaway showing a water-cooled rear turnaround chamber

Two-pass wetback

100 to 800 HP

Three-pass wetback firetube boiler cutaway showing gases passing through the furnace and two tube banks

Three-pass wet