Industrial Boiler FAQs

Answers to the questions plant engineers and facility managers ask us most, about McKenna, equipment, service, permits, rentals, and parts.

SHMU
ASME S · H · M · U

Code-built boilers and vessels

National Board R

Code repairs and alterations

Autoflame
Autoflame

Factory-authorized Tech Center

Limpsfield
Limpsfield

Factory-authorized Burner Tech Center

McKenna flame
Since 1921

Fifth generation, family-owned

QUICK ANSWER

McKenna Boiler Works, Inc. is a fifth-generation, family-owned industrial boiler manufacturer and service company founded in 1921, with its shop in Oceanside, California. It builds firetube, firebox, and vertical boilers, services and repairs other brands, and makes code repairs under its National Board R certificate. This page collects the most common questions about McKenna’s equipment, service, air permits, rentals, parts, and training. For anything not covered, call (323) 987-1816 or email info@mckennaboiler.com.

Company

Questions about McKenna.

McKenna Boiler Works, Inc. is a fifth-generation, family-owned industrial boiler manufacturer and service company founded in 1921, with its shop in Oceanside, California. McKenna designs, builds, installs, and services industrial boiler systems, and services and repairs other brands.

McKenna Boiler Works, Inc. traces its roots to 1887, when J.B. McKenna was servicing boilers in Southern California, and has built boilers since 1921. It is still family-owned, now in its fifth generation.

McKenna Boiler Works, Inc. serves all of California, and most of its customers are in Los Angeles County. Its crews are based throughout Southern California. Equipment is engineered and built at its shop at 2601 Industry Street, Oceanside, California 92054.

McKenna Boiler Works, Inc. holds ASME S, H, M, and U certificates and the National Board R certificate, and maintains a written quality control manual for its code work.

McKenna Boiler Works, Inc. is an ISNetworld member. Every factory and field employee has completed OSHA 10-Hour training, and management has completed OSHA 30-Hour training. Crews work from McKenna’s written safety handbook. To set McKenna up as a contractor at your plant, call (323) 987-1816 or email info@mckennaboiler.com.

Yes. McKenna Boiler Works, Inc. services and repairs Cleaver-Brooks, Superior, Parker, Hurst, Fulton, and other brands. Its National Board R certificate covers code repairs and alterations on boilers and pressure vessels from any manufacturer, and it’s a factory-authorized Autoflame Tech Center and Limpsfield Burner Tech Center.

The McKenna Boiler Works, Inc. service area is all of California. McKenna installs in California and Utah, and starts up and commissions the equipment it builds in any state.

No. McKenna Boiler Works, Inc. builds commercial and industrial boilers for plants, hospitals, campuses, and other facilities. It does not build boilers for houses or apartments.

Equipment

Boilers and boiler room equipment.

McKenna Boiler Works, Inc. builds firetube, firebox, and vertical boilers in its ASME code shop in Oceanside, California, and has been family-owned since 1921. McKenna holds ASME S, H, M, and U certificates and the National Board R certificate, and its own crews install, start up, and service what it builds.

Yes. McKenna Boiler Works, Inc. designs and builds boilers, tanks, and pressure vessels to the customer’s specifications, including equipment sized to fit an existing room or footprint. Send the specifications, drawings, or room dimensions and a McKenna engineer will scope it.

A 150 psig steam boiler is a Section I power boiler. A 150 psig hot water boiler can be built to Section IV, which covers hot water heating boilers up to 160 psi and 250°F. McKenna Boiler Works, Inc. builds firetube steam boilers at 150 and 250 psig to Section I under its S certificate, and hot water boilers at 125 psig to Section IV under its H certificate.

New McKenna Boiler Works, Inc. boilers come with a burner matched to the boiler and the emissions limit, and Autoflame controls come as a standard option. McKenna can recommend Limpsfield and Power Flame burners and Autoflame controls, and will quote a burner from another manufacturer when you prefer one.

Yes. If the customer or engineer prefers a specific burner, McKenna Boiler Works, Inc. will quote it along with other options to compare. McKenna installs, sets up, and tunes burners and controls from any manufacturer, including a brand an engineer or contractor already specified.

Yes. For boilers of 2,000,000 Btu/hr or less, McKenna Boiler Works, Inc. has units pre-certified to South Coast AQMD Rule 1146.2. Under the rule’s June 2024 amendment, gas-fired units up to 2,000,000 Btu/hr must meet 20 ppm NOx today. For boilers that make steam or heat water above 180°F, a zero-emission standard starts January 1, 2029, in new buildings and January 1, 2033, in existing buildings once a unit is 25 years old; lower-temperature units have earlier dates. McKenna will confirm which dates apply to your unit.

McKenna Boiler Works, Inc. is developing an electric boiler for industrial steam and hot water. It is in development and not yet available. Call (323) 987-1816 or see the Electric Boilers page for updates.

Service and repair

Service, maintenance, and repairs.

Yes. A live person answers (323) 987-1816 24 hours a day, and McKenna Boiler Works, Inc. technicians are on call anywhere in California.

An R stamp repair is a repair or alteration to a boiler or pressure vessel made under a National Board R certificate, following the National Board Inspection Code. McKenna Boiler Works, Inc. holds the R certificate and makes code repairs on any brand.

It depends on the boiler, how many hours it runs, and what the plant needs from it. Daily and weekly checks are done by your operators. McKenna Boiler Works, Inc. recommends quarterly combustion tuning and sets a schedule of technician visits, often through an annual service contract.

McKenna Boiler Works, Inc. recommends quarterly combustion tuning to keep boilers in compliance with their air permit and running as efficiently as possible. Your air district rule or permit may set its own schedule. In South Coast AQMD, Rules 1146 and 1146.1 set periodic NOx checks with a portable analyzer, and some low-use units can comply with scheduled tune-ups instead. McKenna technicians are certified by South Coast AQMD for portable analyzer testing.

It depends on the condition of the boiler and how much damage there is. McKenna Boiler Works, Inc. inspects the boiler and quotes the repair. If repairing it is the better value, McKenna repairs it. If replacement makes more sense, McKenna builds replacement boilers in its own shop and can provide a rental boiler to keep the plant running until the new one is in. You get both options from one company.

A McKenna Boiler Works, Inc. annual service contract schedules preventative maintenance visits through the year, with safety control testing, combustion tuning (McKenna recommends quarterly), inspections, inspection prep, and a written report from every visit.

Repairs are quoted separately. During contract visits, McKenna Boiler Works, Inc. notes any deficiencies it finds and quotes the repairs, including code repairs under its National Board R certificate.

Yes. McKenna Boiler Works, Inc. is a factory-authorized Autoflame Tech Center. Its technicians troubleshoot, repair, replace, and commission Autoflame controls, including Mk8 MM and Mini Mk9 controllers, and installed Mini Mk8 systems, on McKenna boilers and other brands. Call (323) 987-1816 when a control panel faults or stops responding.

Usually, yes. Under California’s Boiler and Fired Pressure Vessel Safety Orders (Title 8, Section 781), every boiler covered by the orders must be under the direct supervision of a responsible person. A fired boiler can be left unattended only if it meets the conditions in that section. Those include an audible high and low water alarm the attendant can hear from where they work, a low water cutoff that shuts off the fuel, and checks at intervals of no more than 60 minutes.

Some boilers are exempt from those conditions if they are automatically controlled. Section 771 exempts low-pressure boilers, miniature boilers, and small boilers that stay within all of these limits: 100 psi maximum allowable working pressure, 100 sq. ft. of heating surface, a 16 in. steam drum, 35 gallons of water, and 400,000 BTU/hr burner input.

The attendant must be competent, meaning familiar with the boiler and able to start it safely, feed water, blow it down, and shut it down. Your boiler inspector can confirm what applies to your boilers. McKenna Boiler Works, Inc. offers operator training on the boilers you run.

It depends on where the boiler is. California’s safety orders require a competent attendant, and some cities also require a licensed operator. In the City of Los Angeles, a licensed boiler operator or steam engineer is required for boilers over 5 horsepower that carry steam above 15 psi (LAMC 97.0201). Los Angeles issues a Boiler Operator license for high pressure steam boilers over 5 HP up to 35 HP, and Steam Engineer licenses for boilers up to 500 HP or of any size. A licensed person must be in charge while the boiler runs, and may not be away more than 10 minutes at a time unless the boiler is within their sight or they have unobstructed access to it (LAMC 97.0207). Los Angeles exempts heating and hot water boilers built to ASME Section IV, and steam boilers that operate at 15 psi or less. Check with your city’s building department before a new boiler goes into service. Call McKenna Boiler Works, Inc. at (323) 987-1816 with questions.

Emissions and permits

Air permits, inspections, and NOx.

Burners and retrofits from McKenna Boiler Works, Inc. reach as low as 2.5 ppm NOx (corrected to 3% O2) on select models. Results depend on the boiler, the fuel, and the firing range. McKenna sizes the burner to the boiler and confirms the limit your air district requires.

In most California air districts, yes. Changing a burner usually requires a permit application and a source test. McKenna Boiler Works, Inc. supports the application and the test.

A source test measures a boiler’s actual stack emissions, such as NOx and CO, to show it meets the limits in its air permit. Many air district permits require one after installation or a burner change, and on a set schedule after that. McKenna Boiler Works, Inc. supports the source test with the boiler tuned and ready.

Power boilers in California need a Cal/OSHA permit to operate. The permit is issued after inspection and expires no more than 12 months after the internal inspection. Low-pressure boilers (steam at 15 psi or less, or water at 160 psi or less and 250°F or less), miniature boilers, and the other boilers listed in Title 8 Section 771 don’t need the permit, but still have to meet the Boiler Safety Orders. McKenna Boiler Works, Inc. prepares the boiler and makes the repairs needed to pass.

ASME CSD-1 is the standard for controls and safety devices on automatically fired boilers. It calls for periodic testing of devices such as low water cutoffs, flame safeguards, and fuel valves. McKenna Boiler Works, Inc. performs and documents this testing where CSD-1 applies.

Rentals, parts, and training

Rentals, parts, and operator training.

McKenna Boiler Works, Inc. has steam and hot water rental boilers in a range of sizes. Call (323) 987-1816 with your load, pressure, and fuel, and McKenna will check what’s available.

Yes. Plant crews and contractors can install a McKenna Boiler Works, Inc. rental themselves, or McKenna crews can do the installation. McKenna technicians handle startup and commissioning.

McKenna Boiler Works, Inc. keeps parts in stock from Honeywell, Siemens, Fireye, Autoflame, ASCO, Apollo (Conbraco), Kunkle, United Brass Works, DFT, Armstrong, Everlasting, Ashcroft, Jerguson, McDonnell & Miller, and Warrick, plus feedwater pumps, boiler tubes, and handhole and manway gaskets.

Yes. Parts in stock can be picked up at the McKenna Boiler Works, Inc. shop at 2601 Industry Street, Oceanside, California. Call (323) 987-1816 first to confirm the part is on the shelf.

McKenna Boiler Works, Inc. trains boiler operators for plants across California, in the classroom, hands-on in front of the plant’s own boilers, and at its shop in Oceanside, California.

Don’t see your question? Ask us.

An engineer or technician will answer it.

Serving all of California · Family-owned since 1921

Request a Quote

Tell us what you need.

Fill in what you know. A McKenna engineer will review it and get back to you. Need help now? Call (323) 987-1816.