Service, heat exchanger work, controls repair, and safety testing on Raypak commercial boilers, from an independent company that builds boilers in California.

SHMU
ASME S · H · M · U

Code-built boilers and vessels

National Board R

Code repairs and alterations

Autoflame
Autoflame

Factory-authorized Tech Center

Limpsfield
Limpsfield

Factory-authorized Burner Tech Center

McKenna flame
Since 1921

Fifth generation, family-owned

QUICK ANSWER

McKenna Boiler Works, Inc. services and repairs Raypak boilers for plants across California. McKenna’s crews handle preventive maintenance, CSD-1 safety control testing, combustion tuning, heat exchanger cleaning and replacement, and ignition and controls repair on Raypak boilers. Code repairs are done under McKenna’s National Board R certificate. McKenna is an independent company, not affiliated with Raypak, and builds its own boilers in an ASME code shop in Oceanside, California. Call (323) 987-1816 or email info@mckennaboiler.com to schedule service.

Raypak service

Service for the Raypak boiler you already have.

Raypak is headquartered in Oxnard, California, and its copper fin-tube and condensing boilers heat hospitals, hotels, campuses, and plants across the state. Scale on the heat exchanger, worn ignition parts, and tired controls are the usual service calls.

McKenna services and repairs Raypak boilers with its own crews. We don’t sell Raypak equipment, so the recommendation is what the boiler needs: a repair, an upgrade, or a replacement when the numbers say so.

Raypak XFyre condensing boilers in a mechanical room

What we do

Raypak work McKenna performs.

Raypak scope

Models

All models, including XTherm, Hi Delta, and XVers

Design

Copper fin-tube and condensing hot water boilers

Code work

National Board R certificate, repairs and alterations per the NBIC

Safety testing

ASME CSD-1 control and safety device testing where it applies

Replacement option

For boilers of 2,000,000 Btu/hr or less, McKenna has units pre-certified to South Coast AQMD Rule 1146.2

Controls

Factory controls, Autoflame, or controls from other manufacturers

Service area

All of California

Emergency

A live person answers (323) 987-1816 24/7

How it works

How a Raypak service call runs.

01

Send the nameplate

Call or use the request form. A photo of the nameplate tells us the model, size, and pressure before we arrive.

02

Inspection

A McKenna technician inspects the boiler, burner, controls, and safety devices, and notes what needs work now and what can wait.

03

Written scope

You get a written scope and quote. Code repairs list the R stamp work and the inspector hold points.

04

Repair and test

McKenna does the work, tests the safety controls, tunes the burner, and hands you the paperwork.

Why McKenna

Why plants use McKenna on their Raypak boilers.

Independent

McKenna isn’t tied to a manufacturer’s rep agreement. We recommend what fits your plant, including keeping the boiler you have.

We build boilers

McKenna engineers and builds boilers in its own ASME code shop. That’s the same knowledge we bring to your Raypak.

Code repairs in-house

McKenna holds the National Board R certificate, so welded tube repairs and other pressure part repairs don’t need another company.

One company for the boiler room

We service and repair other brands too. A plant with more than one brand of boiler gets one service company and one set of records.

FAQ