QUICK ANSWER

McKenna Boiler Works, Inc. is a factory-authorized Autoflame Tech Center that installs, commissions, tunes, and services Autoflame controls for plants in Los Angeles and throughout California. McKenna sets up Mk8 MM and Mini Mk9 controllers, EGA analyzers with O2, CO2, and CO trim, and Mk8 DTI monitoring. Autoflame controls come as a standard option on new McKenna boilers. McKenna also installs, sets up, and tunes burners and controls from any manufacturer, including a brand an engineer or contractor already specified. Call (323) 987-1816 or email info@mckennaboiler.com to schedule a site survey.

Linkageless control

What Autoflame controls do on a boiler.

A linkage burner sets fuel and air with one jackshaft and a set of cams. As the linkage wears, the fuel-air ratio drifts, so the burner is set up with extra air to stay safe. The Autoflame Mk8 MM replaces the linkage with separate servomotors on the fuel valve and air damper, and each position is set point by point across the firing range.

Add an EGA and the controller trims the air damper or fan VSD from live O2, CO2, and CO readings in the exhaust. Add a DTI and the plant sees each boiler’s firing rate, pressure or temperature, and alarms on one screen or in the building management system.

California air districts limit NOx and CO from boilers, including South Coast AQMD Rules 1146, 1146.1, and 1146.2, San Joaquin Valley APCD Rules 4306 and 4320, and Bay Area Air District Regulation 9, Rule 7. The burner sets how low NOx can go. Autoflame controls hold the fuel-air ratio the burner was tuned to, so emissions stay steady between tests. See AQMD & Source Testing or estimate fuel savings with the Linkageless Controls Savings Calculator.

Autoflame Mk8 MM micro-modulation burner controller with touchscreen. Image courtesy of Autoflame Engineering Ltd.

Capabilities

What McKenna does with Autoflame controls.

Autoflame equipment we install and service

Mk8 MM controller

Up to 5 servomotors and 2 VSD channels, 4 fuel programs, internal flame safeguard with self-check UV or IR scanning, PID control of steam pressure or water temperature, 12.1 in. touchscreen

Mini Mk9 controller

Autoflame’s current Mini controller, replacing the retired Mini Mk8. Built-in solid-state UV flame sensing, touchscreen, Modbus, BACnet, and Profibus communications. Pairs with the Mk8 EGA EVO for closed-loop trim

Fuels

Natural gas, propane, oil, hydrogen, or a combination

Applications

Steam and hot water boilers, firetube or watertube, including multi-burner boilers

Mk8 EGA EVO analyzer

Standard cells: O2, CO2, CO, and NO. SO2 and NO2 cells optional. Trims on O2, CO2, and CO; correction limited to ±10% by default

Mk8 DTI

Up to 10 Autoflame systems at one site, 2 years of MM and EGA data, Modbus over Ethernet and RS422 to the BMS

Other controls

McKenna installs, sets up, and tunes burners and controls from any manufacturer

Product details from Autoflame’s published manuals and product pages.

How a job runs

How an Autoflame job runs.

01

Site survey

A McKenna technician checks the burner, fuel train, boiler controls, and the plant’s emissions limit, then sends a written scope and quote.

02

Installation

McKenna mounts the controller, servomotors, and any EGA or DTI, and completes equipment wiring to the disconnect.

03

Commissioning

McKenna sets each fuel’s fuel-air curve point by point with a combustion analyzer, then sets up and tests trim and sequencing.

04

Handover and service

Operators get a walkthrough of the controller. McKenna then handles annual service, tuning, and calls when a boiler locks out.